Programme Objectives
By the end of the program, the participants will be able to:
- Demonstrate the Construction of Cables
- Know How to make a H.V Terminals and Joints
- Simply Calculate a Voltage Drop
- Carry Out Maintenance and Testing for Power Cables
Targeted Competencies
Programme Content
- ELECTRICAL CONDUCTORS
- Conductor Materials
- Wire Measurements, U.S. Customary System
- The American Wire Gauge
- Wire Measurements, SI Units
- Stranded Wire
- Resistively
- Temperature Coefficient of Resistance
- PROPERTIES OF CONDUCTORS
- Electrical Wire and Cable Terminology
- Classification of Wires or Cables
- Classification according to Degree of Covering
- Material and Make-up of Electrical Conductors
- Cable Assembly
- Electrical Shielding
- Fillers
- Binder Tapes
- Insulation of Electrical Conductors
- Rubber Insulation
- Code-grade Rubber Compound
- Thermoplastic Insulation
- Thermosetting Insulation
- Mineral Insulation
- Paper Insulation
- Protective covering Materials
- A Pure Lead Sheath
- A Reinforced Lead Sheath
- An alloy Lead Sheath
- Flat band Armour
- Interlocked Armour
- Wire Armour
- Basket Weave Armour
- MI (mineral insulated) Cable
- CABLES, CABLE AMPACITIES AND VOLTAGE DROP
- CABLES
- General
- Power Cables
- General Construction
- Conductors
- Insulation, Covering and Stress Relief
- Cable Stress Relief
- Bedding
- Armouring
- Outer Sheath
- Selection of Power Cables
- Control Cables
- Mineral Insulated Cables
- Method of Specifying Cables
- HIGH VOLTAGE CABLES
- Cables Construction
- Strand Shielding
- Insulation
- Insulation Shielding
- Cable Jacket
- Cable Termination
- Cable Termination Design
- Conductor Ampacities
- Voltage Drop
- Voltage Drop Tables
- Calculations
- Voltage Drop Considerations
- Recommended Limits of Voltage Variation
- CABLES JOINTS AND TERMINAL CONNECTIONS
- Cables Joints and Connections
- Protection of Joints
- Removing Protective Covering
- Removing Insulation
- Cleaning Wire Ends
- Straight Splice for three conductor unshielded cable.
- Straight Splice for three conductor shielded cable
- Scotch Cast in Line Joint
- Terminating Power Cables
- General Instructions
- Termination for unscreened three-core plastic and rubber insulated cables
- Wire Connectors
- Solder less Connectors
- Screw on Pigtail Connectors
- Bolted Type Pressure Connectors
- Run and Tap Connectors
- Bolted Type Lugs
- Terminal Blocks
- Compression Type Connectors and Lugs
- Connector Designation and Marking
- POWER CABLES MAINTENANCE AND TESTING
- MAINTENANCE
- Visual Inspection
- Manhole Installations
- Aerial Installations
- Raceway and Cable Tray Installations
- Remedy of Mechanical Problems
- Remedy of Overheating Problems
- Portable Cable Maintenance
- TESTING
- Insulation Resistance Test (Meggering)
- D.C over-Potential Test (Hi-pot)