High Voltage & Medium Voltage Switchgears & Circuit Breakers

UETMT-ELEC-102 · Electrical

Programme Overview

Switchgear plays an important role in the safe and reliable distribution of electrical power. Failure to quickly and efficiently disconnect faults downstream in the network, or a failure within the switchgear itself is costly, resulting in loss of supply, damage to equipment and possible injury, to personnel.

It is therefore important that switchgear is selected, installed, operated and maintained correctly, embracing an overall ass et management regime that is both economic and effective in securing a high level of system reliability.

This course focuses mainly on medium voltage switchgear associated with power distribution in industrial systems, which comprises by far the bulk of switchgear on most electricity distribution systems. The emphasis is primarily on air-break, SF6 and vacuum circuit breakers, but other forms of MV switchgear, for example ring main units and auto re-closers will also be discussed. Gas insulated equipment, (GIS), for higher voltages will be discussed in some detail.

Programme Objectives

Delegates will gain a detailed appreciation of the following:

  • Types and rating of switchgear - substation layouts and design - indoor and outdoor
  • Switchgear components CT’s, VT’s, protection relays and cable terminations
  • Calculation of fault levels
  • Basic earth fault, unit and overload protection schemes
  • Safe operational policies, including safety rules and safety documents
  • Asset management of equipment
  • Diagnostic tools - insulation testing, partial discharge testing, thermal imaging and potential test equipment.
  • Make and break testing of trip and contact systems test equipment
  • Safe maintenance policies, including safe working practice in switch rooms, indoor and outdoor substations
  • National fault reporting schemes
  • Earthing

Targeted Competencies

  • Types of Switchgear
  • Earth Fault
  • Overload Protection Schemes
  • Arc Characteristics
  • Switchgear Ancillaries
  • Insulation Resistance Testing

Programme Content

Day 1: Introduction to Switchgear

  • Goals of the course – discussion to determine background of participants
  • Evaluation questionnaire – to be completed by participants
  • Single line diagrams – what is a power network? Why different voltage levels?
  • Network components – active and passive –
  • Typical examples
  • Simple busbar and substation layouts –
  • Layouts – protection and control circuits
  • Fault Levels - MVA rating of equipment – 1 and 3 second rating
  • Measuring transformers VT’s and CT’s
  • Circuit breaker utilization, dis connector operation and earthing switches
  • Fuses-LV and HV fuses. Fuse gear. Video of short circuit testing
  • Air break switches – arc chutes and magnet effects.
  • MCC’s for LV distribution boards.
  • Contactors for motor switching.
  • Balanced and earth faults - network and busbar faults
  • Basic system earthing requirements – why earth?
  • Rating of switchgear – normal and fault duties – control and monitoring circuits
  • Selection and checking for correct switchgear ratings - LV, MV, HV and EHV
  • Basic protection relays for unit, overload and earth faults. Back up protection
  • Case study including safety considerations.
  • Effects of loads on switching
  • Energizing and de-energizing transients that can affect the network insulation
  • Worked example of substation fault level and circuit breaker selection for a small petro-chemical installation
  • Wrap up session – what have we achieved today?

Day 2: Distribution Switchgear

  • Primary substations – name plate data
  • Device function numbers – suffix letters, main devices and auxiliary devices
  • Vacuum Switchgear up to 36kV
  • Description of equipment – front, rear, cable entry and busbars
  • Vacuum principles of interruption
  • Air and SF6 external insulation of busbars and vacuum interrupters
  • Voltage withstand levels, 50Hz and lightning impulse
  • HV fuses in combination with, and as an alternative to circuit breakers
  • Oil breakers – do you have these breakers on your system? Discuss!
  • Maintenance requirements air, oil, vacuum
  • SF6 – identify procedures
  • Secondary substations – name plate data –
  • indoor/outdoor equipment
  • Auto-reclosing equipment-dis connectors
  • Typical layouts and selection of equipment
  • Modern SF6 Distribution Switchgear
  • SF6 principles of interruption and insulation –
  • video covering vacuum and SF6
  • Puffer operation and rotating arc breakers
  • Contacts – vacuum and SF6 -measurement of wear and contact resistance
  • Rotating arc concept
  • Gas Insulate Switchgear, SF6 -what are the maintenance problems?
  • Single phase and Trefoil arrangements for busbars
  • Maintenance and testing requirements for vacuum and SF6
  • Operational arrangements for a range of typical
  • breakers up to 45kV
  • Wrap up session - SF6 -v-vacuum delegate discussion – practical issues!

Day 3 : Switching, Safety and Earthing Requirements

  • Busbar configurations – single, double, sectionalized and breaker and a half
  • Main substation earthing and bonding for 50Hz
  • Step and touch potentials – danger to personnel
  • Routine testing and certification of substation earthing
  • Interrupter classification-mechanisms, motor-spring, hydraulic and solenoid
  • Switching Requirements –interrupting time, sym/ asymmetric waveforms
  • Surge arrestors for lightning protection - ratings
  • Auto-reclosing considerations – ring main and radial circuits
  • Safe working in a substation environment
  • Mechanisms of deterioration in insulation - water, mechanical vermin, human
  • General safety precautions and the use of personal protective equipment
  • Principles of safety rules and safety policy –personal authorization?
  • Operative training for safe operation of switchgear – isolation of breaker
  • Safety documentation and safety interlocks key/padlock procedures
  • Operational and safety locking, caution and danger notices
  • Substation alarms

Using drawings and manufacturers literature identify suitable layouts then:

  • Example - team exercises using above information
  • Day 4: HV Gas Insulated Switchgear and Auxiliary Plant Maintenance
  • 145kV, 3 phase arrangement and single 275/400kV SF6 arrangements
  • Arc characteristics – closing and opening – short circuit testing -standards
  • Switchgear ancillaries, measurement CTs, VTs, relays –complex protection
  • SF6 parameters - filling pressures and dew point considerations - hazards?
  • Decomposition of arced SF6.
  • Handling contaminated materials – disposal!
  • Inspection and routine maintenance –earthing for safe working! Gas carts
  • Equipment required for maintenance –investigating leaks
  • Insulation resistance testing
  • Mechanism testing and auxiliary relay contact circuits –trip coils open/close
  • Contact trip timing tests and record interpretation – contact resistance tests
  • Testing of MV and HV Switchgear-partial discharge diagnostic tests
  • Thermal imaging – simple and complex
  • Power Factor tests – voltage pressure tests AC, DC!
  • Fault recording and reporting –national data base of faults
  • Maintenance records
  • Health and Safety
  • Test: Write down routine tests required for the various types of switchgear.
  • How often should they be performed? What is the short circuit rating of equipment? How do you go about carrying out a switching operation?
  • Wrap up session - discuss your own experience of maintenance policies

Day 5: Maintenance and Testing

  • Switchgear defects and defect control systems
  • Health and Safety in Substations
  • Mechanisms of deterioration of insulation
  • MCC testing and refurbishment - contacts and arc chutes
  • Troubleshooting – use of diagrams and manufacturers manuals
  • Block diagrams, line diagrams, wiring diagrams, interlock diagrams
  • Required maintenance – condition, heaters, fuses, mechanism, overhaul
  • Weekly, monthly, yearly program of maintenance – 5 years and more?
  • Principles of circuit breaker maintenance –mechanisms and mechanical aspects
  • Maintaining vacuum circuit breakers –equipment required
  • Maintaining SF6 circuit breakers –equipment required SAFETY!
  • Protection unit and busbar
  • Relay testing – time/current test, pick up current, zero checks, drop out
  • CT and VT check
  • Case histories of failures – how to investigate and report
  • Asset management - refurbish or replace?
  • Discussion time
  • Wrap up session - Have we got there?
  • It is intended to use several design examples to illustrate the points being made in the main material.
  • Numerous types of breakers will be referred to from a range of manufacturers.